■IT-480S, IT-480L
Type | Micro-spot type | Spot type |
---|---|---|
Model | IT-480S | IT-480L |
Spectral response | 8μm to14μm | |
Measured temperature range | -50℃ to 500℃ | |
Output | USB (resolution = 0.1℃) Current (4 mA to 20 mA, resolution =0.24μA, non-insulated) | |
Currnent output range | -50℃ to 500℃ (factory setting 0℃ to 500℃) | |
Accuracy | 〔USB Output〕 Within ±(-8%rdg+1)℃[-50℃ to 0℃] Within ±1℃[ 0℃ to 200℃] Within ±0.5%rdg℃[200℃ to 500℃] 〔Current Output〕 Difference from USB data is within ±(0.1% output range )℃ | |
Repeatability | 0.5℃ or less | |
Response Time | Current output 0.14 s or less (95% response, moving average count is 1.) | |
Measurement diameter | φ3 mm/ distance 30 mm | φ8 mm/ distance 100 mm |
Temperature drift | Within ±0.5℃/℃[-50℃ to 0℃] Within ±0.25℃/℃[0℃ to 500℃] | |
Emissivity | Factory setting: 0.950 (Setting range is 0.100 to 1.999.) | |
Ambient temperature / humidity | Temperature: 0°C to 55°C Humidity: 35% to 85% (No condensation) | |
Power supply | USB bus power /12 V DC to 24 V DC | |
Power consumption | 30 mA or less (at 24 V DC) | |
Material of the body case | Aluminum | |
Mass | Approx. 95 g (Body only. Excluding cable and metal brackets) | |
Sight | Setting gauge |
■IT-480N, IT-480W, IT-480F, IT-480P
Type | General purpose type | Narrow view type |
---|---|---|
Model | IT-480N / IT-480W*1 | IT-480F / IT-480P*1 |
Spectral response | 8μm to 14μm | |
Measured temperature range | -50℃ to 500℃ | -50℃ to 1000℃ |
Output | USB (resolution = 0.1℃) Current (4 mA to 20 mA, resolution =0.24μA, non-insulated) | |
Currnent output range | -50℃ to 500℃ (factory setting 0℃ to 500℃) | -50℃ to 1000℃ (factory setting 0℃ to 500℃) |
Accuracy | 〔USB Output〕 Within ±(-8%rdg+1)℃ [-50℃ to 0℃] Within ±1℃ [ 0℃ to 200℃] Within ±0.5%rdg℃ [200℃ to 500℃] 〔Current Output〕 Difference from USB data is within ±(0.1% output range )℃ | 〔USB Output〕 Within ±(-8%rdg+1)℃ [-50℃ to 0℃] Within ±1℃ [ 0℃ to 200℃] Within ±0.5%rdg℃ [200℃ to 1000℃] 〔Current Output〕 Difference from USB data is within ±(0.1% output range )℃ |
Repeatability | 0.5℃ or less | Within 1℃[ -50℃ to 0℃] Within 0.5℃[ 0℃ to 500℃] Within 1℃[ 500℃ to 1000℃] |
Response Time | Current output 0.14 s or less (95% response, moving average count is 1.) | |
Measurement diameter | φ72 mm/ distance 1000 mm | φ35 mm/ distance 1000 mm |
Temperature drift | Within ±0.5℃/℃ [-50℃ to 0℃] Within ±0.25℃/℃ [0℃ to 500℃] | Within ±0.5℃/℃ [-50℃ to 0℃] Within ±0.25℃/℃ [0℃ to 500℃] Within ±0.5℃/℃ [500℃ to 1000℃] |
Emissivity | Factory setting: 0.950 (Setting range is 0.100 to 1.999.) | |
Ambient temperature / humidity | Temperature: 0°C to 55°C Humidity: 35% to 85% (No condensation) | |
Power supply | USB bus power / 12 V DC to 24 V DC | |
Power consumption | 30 mA or less (at 24 V DC, laser: OFF) 40 mA or less (at 24 V DC, laser: ON) | |
Material of the body case | Aluminum | |
Mass | Approx. 95 g (Body only. Excluding cable and metal brackets) | Approx. 115 g (Body only. Excluding cable and metal brackets) |
Sight | Laser (Class 1)*1 |
*1) IT-480W 및 IT-480P에 레이저 포인터가 장착되지 않음
악세사리
IT-480 데이터 수집 소프트웨어인 'IT-480 Data Acquisition' 은 방사 온도계 IT-480 시리즈 전용 소프트웨어입니다. IT-480 Data Acquisition은 USB를 통해 개인용 컴퓨터에 연결된 IT-480에 대한 다양한 설정, 작동 점검 및 데이터 수집을 확인/변경할 수 있습니다.
*해당 소프트웨어는 무료로 다운로드 가능하며 해당 소프트웨어 없이도 IT-480의 사용은 가능합니다. (현재 출력: 4 mA ~ 20 mA)
다운로드 가능한 아이템
• IT-480 설명서
• 데이터 수집 소프트웨어 'IT - 480 Data Acquisition'
o 32비트.zip
o 64비트.zip
o IT-480 데이터 수집용 사용 설명서
• IT-480용 가상 COM 포트 드라이버
o 드라이버.zip
IT-480과의 직렬 통신은 'Tera Term'과 같은 통신 소프트웨어나 IT-480용 가상 COM 포트 드라이버를 개인용 컴퓨터에 설치하여 고객이 만든 프로그램과 함께 이용 가능합니다.
IT-480에 대한 다양한 설정 및 측정값 수집 확인/변경 시리얼 통신이 가능하며 데이터 수집 소프트웨어 'IT - 480 Data Acquisition'만 사용할 경우에는 가상 COM 포트 드라이버의 설치가 따로 필요하지 않습니다.
o IT-480 가상 COM 포트 드라이버 참조 설명서
해당 소프트웨어는 Windows 7, Windows 8, Windows 8.1, Windows 10(32비트, 64비트)이 장착된 개인용 컴퓨터 또는 태블릿에서 작동 가능합니다.
(작업 점검은 공장에서 진행하지만 모든 장치에 대한 작동을 보장하지는 않음.)