HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HC-300F는 불소이온전극(#1009)을 연결하여 시료수 내 유리불소이온을 검출합니다.
(총 불소는 검출하지 않습니다.)
반도체 FPD 및 유리 제조업체와 같은 공장의 폐수에서 불소 이온 모니터링에 적합 합니다.

- 측정 범위 : 0~10,000mg/L
- 온도 : 0 ~ 100℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process
      Operating temperature range(Transmitter):-20 - 60℃
      Rated voltage: DC 24 V
      Robust aluminum die cast  (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • 0 to 10,000 mg/L wide measurement range (10-range switching)
  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Sensor error can be detected immediately by self-diagnosis function
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring

Converter rating

Product name Fluoride ion meter
Model HC-300F
Measurable range 0 mg/L to 10000 mg/L (Display range: 0 mg/L to 11000 mg/L)
Available range options:
10000, 5000, 2000, 1000, 500, 200, 100, 50, 20.0, 10.0 mg/L
0℃ to 100℃ (Display range: -20℃ to 130℃)
Display
resolution
Concentration 0.1 mg/L: 0.0 mg/L to 20.0 mg/L
1 mg/L: 0 mg/L to 200 mg/L
10 mg/L: 0 mg/L to 2000 mg/L
100 mg/L: 0 mg/L to 10000 mg/L
Temperature 0.1℃
Performance Concentration Repeatability Within ±7% of the full scale (response for equivalent input)
Linearity Within ±10% full scale (response for equivalent input)
Temperature Repeatability ±0.3℃ (response for equivalent input)
Linearity ±0.3℃ (response for equivalent input)
Transmission
output
Output type 4 mA to 20 mA DC, input/output isolated type
Load resistance Max. 600Ω (case of 24 V DC power supply)*1
Linearity Within ±0.08 mA (output only)
Repeatability Within ±0.02 mA (output only)
Output range Concentration: Selection from preset ranges or free range input within measuring range.
Occasional out for error Hold or burnout to either 3.8 mA or 21 mA
Transmission hold In the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact input Number of input points 1
Contact type No-voltage a contact for open collector
Conditions ON resistance: 40Ω
Open voltage: 1.2 V DC
Short-circuit current: 21 mA DC max.
Contact function External input for transmission holding.
Temperature
compensation
Applicable temperature element Platinum resistor: 1 kΩ (0℃)
Positive relation resistor with temperature: 10 kΩ (25℃)
0℃ to 100℃
Temperature calibration 1 point calibration comparing reference thermometer
Calibration Number of calibration points Selectable from 1, and 2 points
Kinds of standard solutions The first point: Calibrated by the standard solution with the density from
50 to 100% of the measuring range.
The second point: Calibrated by the standard solution with the density
from 1 to 20% of the measuring range.
Additional capabilities Automatic detection of calibration failure (asymmetry potential,
sensitivity, or response time)
Calibration history (asymmetry potential, sensitivity, and number of days elapsed after last calibration)
Self-check Calibration error Asymmetry potential error, and sensitivity error
Temperature calibration error
Electrode diagnostic error Temperature sensor short-circuit, temperature sensor disconnection,and out of the temperature measurement range
Meter error CPU error, ADC error, and memory errors
Operating temperature range -20℃ to 60℃ (without freeze)
Operating humidity range Relative humidity: 5% to 90% (without condensation)
Storage temperature -25℃ to 65℃
Power supply Rated voltage 24 V DC (operating voltage range: 21 V to 32 V DC)*1
Power consumption 0.6 W (Max)
Compatible
standards
CE marking EMC directive: EN61326-1
RoHS Directive: EN50581
EMC Immunity
Industrial
electromagnetic
environment
Electrostatic discharge IEC61000-4-2
Electromagnetic field at radiated radio frequency IEC61000-4-3
Electric fast transient/burst IEC61000-4-4
Surge IEC61000-4-5*2
Conducted interference induced by radio
frequency
IEC61000-4-6
Emission
Class A
Radiated disturbance CISPR 11 CLASS A
FCC rules Part15 Class A
Structure Installation Outdoor installation type
Installation method Mount on 50 A pole or wall
Protection code IP65 IEC60529, JIS C 0920
Case material Aluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittings SUS304
Material of hood SUS 304 stainless steel
(coated with epoxy-denatured melamine resin)
Material of window Polycarbonate
Display element Reflective monochrome LCD
External dimensions 180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
Mass Main body: Approx. 2.8 kg; cover and mounting brackets: Approx. 1 kg

 

*1: The max. load resistance is available within the range shown in the figure below, depending on power supply voltage:

Relation between power supply voltage and load resistance

*2: When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

Note

For transmission output, an arrester (spark-over voltage: 400 V) is implemented. However, use the optimal surge absorption element on the connection line in accordance with the ambient environment, equipment installation situation, externally connection equipment, and others.

 

Electrode rating

Product name Fluoride ion electrode
Model 1009
Sample water
conditions
pH range 4pH to 8pH (at 0.2 mg/L)
4pH to 10pH (at 20 mg/L)
4pH to 12pH (at 2000 mg/L)
Temperature range 0℃ to 40℃
Electric conductivity 500 μs/cm or more
Flow rate range 1 cm/sec to 20 cm/sec
Electrode structure Structure Submersible type
Response film Lanthanum fluoride
Comparative electrode Ag/AgCl, Internal solution KCL3.3 mol/L, Replenishment type
Liquid junction Ceramic double junction
Temperature
compensation element
Pt1000 Ω (0℃)
Cable length 5 m
External dimensions 12φ mm × 175 (L) mm (cable and projection excluded)
Mass Approx. 200 g
Option Holder CH-10 (Immersion type holder)
CF-30 (Inline type holder)
Cleaning device JCH-12 (Immersion type water-jet cleaning device)
JCH-32 (Circulation type water-jet cleaning device)

 

Note

  • This monitor detects the free fluoride ions in liquids, but it does not detect all fluorides. When complexes are present, a measurement lower than JIS will result.
  • Measurements may vary depending upon the pH level. Use this monitor in close to neutral pH conditions.

제품 문의