HE-300R

現場安裝型電阻率計(電阻率計)

用於測量UPW(超純水)的電阻率。

與電阻率感測器(ERF系列)組合,測量水溶液的電阻率和溫度。適用於測量超純水的電阻率。

RESIST

產品分類: Process Water
製造商: HORIBA Advanced Techno Co., Ltd.

Enables measurements with minimal error

Measurements are affected less by ambient temperature and sample temperature, enabling accurate measurements with less error.

We provide equipment and sensor calibration services

Temperature sensor offset calibration is offered as well as transmitter and sensor combination calibration services. *Option

Highly responsive temperature sensor

Helps to minimize fluctuations in measurement values due to delayed temperature compensation in the event of sudden changes in water temperature.

Product nameResistivity meter
ModelHE-300R
Sensors in
combination
2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm
Measuring rangeResistivityMΩ•cm0.000 to 2.0000.00 to 20.00 (*1)
kΩ•cm0.00 to 20.000.0 to 200.0 (*1)
Temperature0℃ to 100℃ (Display range: −10℃ to 110℃)
Display
resolution
ResistivityAs shown in the measuring table.
Temperature0.01℃
PerformanceResistivityRepeatabilityWithin ±0.1% of the full scale (response for equivalent input)
LinearityWithin ±0.5% of the full scale (response for equivalent input)
TemperatureRepeatability±0.1℃ (response for equivalent input)
Linearity±0.5℃ (response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC: input/output isolated type
Load resistanceMaximum: 600Ω  Case of 24 V DC power supply
Linearity±0.08 mA (output only)
Repeatability±0.02 mA (output only)
Output rangeResistivity: Free setting within a measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact inputNumber of input1
Contact typeNo-voltage "a" contact for open collector
ConditionsON resistance: 40 Ω max.
Open voltage: 1.2 V DC
Short-circuit current: 21 mA max.
Contact functionExternal input for transmission holding.
Temperature
compensation
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
Compensation method
  • Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: +/−3%/℃)
  • No temperature compensation
    One of the three ways of compensation is selectable.
    (In the de-ionized water area, the temperature compensation for pure water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
Temperature compensation
range
0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.)
CalibrationResistivityBased on parameter input of coefficient for the sensor cell constant.
TemperatureComparison to the accurate thermometer
Both deviation and coefficient of RTD are taken into account for calibration.
Other functionUPW standard resistivity inputSelect one from the next.
182.3 kΩ•m (standard), 181.8 kΩ•m, 182.4 kΩ•m,
18.23 MΩ•cm (standard), 18.18 MΩ•cm, or 18.24 MΩ•cm
Clipping functionIf the measured value exceeds the user setting value for clipping, the measured data will be held at the clipping value.
Self-checkElectrode diagnostic errorTemperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range
Meter errorCPU, ADC, and memory errors
Operating
temperature
range
−20℃ to 60℃ (without freeze)
Operating
humidity range
Relative humidity: 5% to 90% (without condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage24 V DC (operating voltage range: 21 V to 32 V DC)
Power consumption0.6W max.
Compatible
standards
CE markingEMC directive: EN61326-1
RoHS Directive: EN50581
 Immunity
Industrial
electromagnetic
environment
Electostatic dischargeIEC61000-4-2
Electromagnetic field of radiated radio frequencyIEC61000-4-3
Electric fast transient/burstIEC61000-4-4
SurgeIEC61000-4-5 (*3)
Conducted interference induced by radio frequencyIEC61000-4-6
Emission
ClassA
Radiated disturbanceCICPR 11 CLASS A
Noise terminal voltageCISPR 11 CLASS A
FCC RulesPart15 CLASS A
StructureInstallationOutdoor installation type
Installation methodMount on 50 A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of coverSUS304 stainless steel (coated with epoxy-denatured melamine resin)
Material of display
window
Polycarbonate
Display elementReflective monochrome LCD
External
dimensions
180 (W)  × 155 (H)  × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 2.8 kg; cover and mounting brackets: Approx. 1 kg

Note

  • Note 1  : Without temperature compensation, 0.0-100.0 MΩ•cm(0-1000 kΩ•m) can be displayed.
  • Note 2  : The maximum load resistance that can be connected is decided depending on the powersupply voltage.

 

Relation between power supply voltage and load resistance

  • Note 3  : When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.
  • Note 4  : An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

更多推荐

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA PC210
LAQUA PC210

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HT-110
HT-110

On-line TOC analyzer

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUAtwin EC-11
LAQUAtwin EC-11

Pocket Water Quality Meters

LAQUAtwin EC-22
LAQUAtwin EC-22

Pocket Water Quality Meters

LAQUAtwin EC-33
LAQUAtwin EC-33

Pocket Water Quality Meters

LAQUAtwin Salt-11
LAQUAtwin Salt-11

Pocket Water Quality Meters

LAQUAtwin Salt-22
LAQUAtwin Salt-22

Pocket Water Quality Meters

PM-960, PM-100
PM-960, PM-100

Peracetic acid concentration monitor

Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L
Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L

Insertion sensor type for wide-range conductivity meter HE-960HI

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

Corporate