透過採用新設計的溫度測量電路,高階電阻率表可顯著改善UPW(超純水)和高溫純水的電阻率測量的關鍵溫度補償性能。高度穩定的電阻率測量是透過不僅在水溫下而且在環境溫度下的變化來實現的。

RESIST

產品分類: Process Water
製造商: HORIBA Advanced Techno Co., Ltd.

Enables measurements with minimal error

Measurements are affected less by ambient temperature and sample temperature, enabling accurate measurements with less error.

Highly responsive temperature sensor

Helps to minimize fluctuations in measurement values due to delayed temperature compensation in the event of sudden changes in water temperature.

We provide equipment and sensor calibration services

Temperature sensor offset calibration is offered as well as transmitter and sensor combination calibration services. *Option

2-channel specification

Allowing measurement at 2 points, and capable of displaying salt removal rate.

Product nameIndustrial 2-channel specific resistance meter
ModelHE-960RW
Measurement
method
Electrode type (2-electrode method)
Sensor input2 channels (for concurrent measurement with sensors isolated each other)
Cell constant0.01/cm
Temperature sensor
specifications
Platinum resistance 1000 Ω/0℃
Measuring rangeMeasurement unitkΩ•m0 to 20.00 to 200.00 to 1000 *
MΩ•cm0 to 2.000 to 20.000 to 100.0 *
*: Measurable without temperature compensation
Temperature    
  
0℃ to 100℃
(The number of digits after the decimal point is selectable from one and two. The range of measurements is −20℃ to 120℃.)
Desalination rate0% to 100%
Temperature: 0℃ to 100℃ (Select your desired decimal point from 0, 1, and 2 digits.)
RepeatabilityWithin ±0.1% of the full scale (in equivalent input)
LinearityWithin ±0.5% of the full scale (in equivalent input)
Transmission
output
Number of outputs: 2
4 mA to 20 mA DC/0 mA to 20 mA DC, input/output isolated type
Maximum load resistance: 900 Ω
Transmission output range: Freely selectable within the measurement range
(Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.)
Contact outputNumber of outputs: 4
Alarm contact outputs (R1, R2, and R3)
  Contact type: relay contact, SPST (1a)
  Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
  Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis
  Selectable from the selected measurement, anomaly alarm, and maintenance.
Alarm contact output (R4)
  Contact type: relay contact, SPDT (1c)
  Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
  Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis
  Selectable from the selected measurement, anomaly alarm, and maintenance.
  (However, R1 and R2, and R3 and R4 share the common contacts respectively.)
Calibration functionSpecific resistance: Based on the specified compensation coefficient for cell constant (parameter input)
Temperature: Calibrated by comparing with the reference thermometer
Communication
output
RS-485 input/output
Transmission
output hold feature
  • Previous value hold
  • Optional value hold
    Selectable from the above (However, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function
  • Sensor diagnosis
    Short-circuit and disconnection of the temperature sensor
  • Out of the measurement range
  • Converter error
Temperature
compensation
  • Temperature compensation for extra-deionized water and impurities
      Select the temperature characteristics of impurities
      - NaCl temperature characteristics
      - Arbitrary temperature coefficient entry (temperature coefficient: 5%/℃)
      Reference temperature: 5℃ to 95℃
  • No temperature compensation is performed.
Temperaturecompensated
range
0℃ to 100℃
Extra deionized
water specific
resistance selection
Measurement
unit
kΩ•m182.3 (standard), 181.8, 182.4Select from options shown on the left.
MΩ•cm18.23 (standard), 18.18, 18.24
Clipping functionWhen the measured value is above the upper limit of the measurement range derived from the specified specific resistance, the specified resistance is used as the measured value.
Ambient
temperature
−5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directives: EN61326-2-3
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC Part15
External
dimensions
96 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm (when panel-mounted)
MassApprox. 550 g
Compatible sensorsERD/ERF-series specific resistance sensor, cell constant 0.01/cm

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

更多推荐

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA PC210
LAQUA PC210

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HT-110
HT-110

On-line TOC analyzer

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUAtwin EC-11
LAQUAtwin EC-11

Pocket Water Quality Meters

LAQUAtwin EC-22
LAQUAtwin EC-22

Pocket Water Quality Meters

LAQUAtwin EC-33
LAQUAtwin EC-33

Pocket Water Quality Meters

LAQUAtwin Salt-11
LAQUAtwin Salt-11

Pocket Water Quality Meters

LAQUAtwin Salt-22
LAQUAtwin Salt-22

Pocket Water Quality Meters

PM-960, PM-100
PM-960, PM-100

Peracetic acid concentration monitor

Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L
Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L

Insertion sensor type for wide-range conductivity meter HE-960HI

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

Corporate