Product nameIndustrial conductivity meter
ModelHE-480H
Measurement
method
Electrode type (4-electrode method)
Cell constant1.0/cm
Measuring range*Measurement range
(S/m)
0.000 to 2.0000.00 to 20.000.00 to 50.00
Measurement range
(mS/cm)
0.00 to 20.000.0 to 200.00.0 to 500.0
Seawater salinity
conversion value (%)
0.00 to 4.00
NaCl salinity
conversion value (%)
0.0 to 20.0
Temperature0℃ to 100℃
(The displayed decimal place is selectable among 0, 1, and 2.)
RepeatabilityConductivity displayWithin ±0.5% of the full scale(in equivalent input)
Salinity conversion displayWithin ±1% of the full scale
LinearityConductivity displayWithin ±0.5% of the full scale(in equivalent input)
Salinity conversion displayWithin ±1% of the full scale
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900Ω
Transmission output range: Freely selectable within the measurement range
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
 Contact type: relay contact, SPDT (1c)
 Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
 Contact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Calibration functionConductivity: Based on the specified compensation coefficient for the cell constant
(parameter input)
Temperature: Calibrated by comparing with the reference thermometer
Transmission
output hold feature
  • Previous value hold
  • Optional value hold
  • Continuous
    Selectable from the above (However, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function
  • Sensor diagnosis
    Short-circuit and disconnection of the temperature sensor
  • Out of the measurement range
  • A/D converter scale over
  • Converter error
Temperature
compensation
  • Temperature characteristics of NaCl
  • Freely selectable reference temperature and temperature coefficient
Measurement rangeReference
temperature
Temperature
coefficient
0.000 S/m to 2.000 S/m
(0.00 mS/cm to 20.00 mS/cm)
5℃ to 95℃±5%/℃
0.00 S/m to 20.00 S/m
(0.0 mS/cm to 200.0 mS/cm)
25℃±3.5%/℃
0.00 S/m to 50.00 S/m
(0.0 mS/cm to 500.0 mS/cm)
No temperature compensation
  • No temperature compensation
Temperature compensated range0℃ to 100℃
Ambient
temperature
-5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
-25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC Part15
External
dimensions
48 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g
Compatible sensorsFES series conductivity sensor, cell constant 100/m (1.0/cm)
(The measurement range differs depending on the sensor model.)

* Sensors and measurement ranges

 

Sensor modelFES-125
FES-125F
FES-126
FES-126F
FES-105
FES-105F
FES-116
FES-116F
Measurement
range
0.000 S/m to 2.000 S/m
(0.00 mS/cm to 20.00 mS/cm)
0.00 S/m to 20.00 S/m
(0.0 mS/cm to 200.0 mS/cm)
 
0.00 S/m to 50.00 S/m
(0.0 mS/cm to 500.0 mS/cm)
 
Seawater
salinity
conversion
value
0.00% to 4.00%
NaCl salinity
conversion
value
0.0% to 20.0% 
Temperature0℃ to 50℃
0℃ to 100℃  

✔ Applicable

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

更多推荐

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA PC210
LAQUA PC210

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HT-110
HT-110

On-line TOC analyzer

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUAtwin EC-11
LAQUAtwin EC-11

Pocket Water Quality Meters

LAQUAtwin EC-22
LAQUAtwin EC-22

Pocket Water Quality Meters

LAQUAtwin EC-33
LAQUAtwin EC-33

Pocket Water Quality Meters

LAQUAtwin Salt-11
LAQUAtwin Salt-11

Pocket Water Quality Meters

LAQUAtwin Salt-22
LAQUAtwin Salt-22

Pocket Water Quality Meters

PM-960, PM-100
PM-960, PM-100

Peracetic acid concentration monitor

Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L
Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L

Insertion sensor type for wide-range conductivity meter HE-960HI

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

Corporate