HO-300

現場安裝型ORP計

HORIBA 長期暢銷的水質計在室內和室外應用中均表現出色。

適用於曝氣池、反硝化池等中和反應製程的管理。我們提供各種清潔設備來適應各種樣品。

產品分類: Process Water
製造商: HORIBA Advanced Techno Co., Ltd.

Comprehensive range of cleaning devices.

A diverse lineup of cleaning devices are offered.  Particularly, ultrasonic cleaners are advantageous as they do not require water or air, making them convenient for retrofitting existing HO-300 installations on site. The drop-in type of cleaning device, which fits into a holder, offers ease of maintenance.

Product nameORP meter
ModelHO-300
Combined sensorORP electrode
Measurable
range
ORP−2000 mV to 2000 mV (display range: −2200 mV to 2200 mV)
Temperature0℃ to 100℃
  • Display range :−10℃ to 110℃
    (the sensor types are detected automatically)
  • Display range :−20℃ to 130℃
    (the sensor types are input by manually)
Display
resolution
ORP1 mV
Temperature0.1℃
PerformanceORPRepeatabilityWithin ±5mV (response for equivalent input)
LinearityWithin ±5mV (response for equivalent input)
TemperatureRepeatability±0.3℃ (response for equivalent input)
Linearity±0.3℃ (response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC: input/output insulation type
Load resistanceMax.: 600Ω (case of 24 V DC power supply)*1
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeORP: Selection from preset ranges or free range input within measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact inputNumber of input points1
Contact typeNo-voltage a-contact
ConditionsON resistance: 40 Ω
Open voltage: 1.2 V
Short-circuit current: 21 mA DC max.
Contact functionExternal input for transmission holding.
Temperature
measurement
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
Positive relation resistor with temperature:
500 Ω (25℃), 6.8 kΩ (25℃), 10 kΩ (25℃)
Element selection methodAutomatic temperature sensor type detection or manual selection (no temperature element is selectable)
CalibrationORP adjust functionAdjust (offset adjustment): −200 mV to 200 mV
Span sensitivity correction: 0.500 to 1.500
Temperature calibration1 point calibration comparing reference thermometer
Self-checkCalibration errorTemperature calibration error
Out of temperature calibration range (for ORP sensor with RTD).
Electrode diagnostic errorReference electrode impedance error (only applicable for differential circuit mode with a liquid contact electrode)
Temperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range
Converter errorCPU, ADC, and memory errors
Operating temperature range−20℃ to 60℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature−25℃ to 65℃
Power supplyRated voltage24 V DC (operating voltage range: 21 V to 32 V DC)*1
Power consumption0.6 W or less.
Compatible
standards
CE marking 
 Compatible standardsEMC directive: EN61326-1
RoHS Directive: EN50581
ImmunityIndustrial electromagnetic environment
Electostatic dischargeIEC61000-4-2
Electromagnetic field of radiated radio frequencyIEC61000-4-3*2
Electric fast transient/burstIEC61000-4-4
SurgeIEC61000-4-5*3
Conducted interference induced by radio frequencyIEC61000-4-6*2
EmissionClass A
Radiated disturbanceCICPR 11 CLASS A
FCC RulesPart15 CLASS A
StructureInstallationOutdoor installation type
Installation methodMounted on 50 A pole or wall
Protection codeIP65IEC60529, JIS C0920
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS304 (coated with epoxy modified melanine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) mm × 155 (H) mm × 115 (D) mm (excluding mounting brackets)
MassMain body: approx. 2.8 kg, Hood and mounting brackets: approx. 1 kg
  • *1:  The max. load resistance that can be connected is decided depending on the power-supply voltage.

 

Relation between power supply voltage and load resistance

Relation between power supply voltage and load resistance

  • *2:  The influence of the ORP reading by the electromagnetic field of radiated radio frequency or the conducted interference induced by radio frequency is within 6mV.
  • *3:  When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.

Note

Though an arrester (spark over voltage: 400 V) is implemented for transmission output, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

更多推荐

300-O-C ORP Sensor Cartridge
300-O-C ORP Sensor Cartridge

ORP Sensor Cartridge for WQ-300 series

9301-10D ORP electrode
9301-10D ORP electrode

Plastic body Non-refillable ORP electrode

Glass Electrode 1076A-10C
Glass Electrode 1076A-10C

For measurement of low-conductivity water and non-aqueous solvents.

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA PC210
LAQUA PC210

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD2000
LAQUA PD2000

Benchtop pH/ORP/Ion/DO/BOD/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

LAQUA PD220
LAQUA PD220

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

LAQUA PH1100
LAQUA PH1100

Benchtop Water Quality Meters

LAQUA PH1200
LAQUA PH1200

Benchtop Water Quality Meters

LAQUA PH1300
LAQUA PH1300

Benchtop Water Quality Meters

LAQUA PH1500
LAQUA PH1500

Benchtop Water Quality Meters

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

LAQUA PH220
LAQUA PH220

Handheld pH/ORP/Temperature Meter

LAQUA WQ-310-K
LAQUA WQ-310-K

Handheld Water Quality Meters

LAQUA WQ-320-K
LAQUA WQ-320-K

Handheld Water Quality Meters

LAQUA WQ-330-K
LAQUA WQ-330-K

Handheld Water Quality Meters

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HT-110
HT-110

On-line TOC analyzer

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUAtwin EC-11
LAQUAtwin EC-11

Pocket Water Quality Meters

LAQUAtwin EC-22
LAQUAtwin EC-22

Pocket Water Quality Meters

LAQUAtwin EC-33
LAQUAtwin EC-33

Pocket Water Quality Meters

LAQUAtwin Salt-11
LAQUAtwin Salt-11

Pocket Water Quality Meters

LAQUAtwin Salt-22
LAQUAtwin Salt-22

Pocket Water Quality Meters

PM-960, PM-100
PM-960, PM-100

Peracetic acid concentration monitor

Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L
Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L

Insertion sensor type for wide-range conductivity meter HE-960HI

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

Corporate