Product name | Industrial 2-channel specific resistance meter |
Model | HE-960RW |
Measurement method | Electrode type (2-electrode method) |
Sensor input | 2 channels (for concurrent measurement with sensors isolated each other) |
Cell constant | 0.01/cm |
Temperature sensor specifications | Platinum resistance 1000 Ω/0℃ |
Measuring range | Measurement unit | kΩ•m | 0 to 20.0 | 0 to 200.0 | 0 to 1000 * |
MΩ•cm | 0 to 2.00 | 0 to 20.00 | 0 to 100.0 * |
*: Measurable without temperature compensation |
Temperature | 0℃ to 100℃ (The number of digits after the decimal point is selectable from one and two. The range of measurements is −20℃ to 120℃.) |
Desalination rate | 0% to 100% |
Temperature: 0℃ to 100℃ (Select your desired decimal point from 0, 1, and 2 digits.) |
Repeatability | Within ±0.1% of the full scale (in equivalent input) |
Linearity | Within ±0.5% of the full scale (in equivalent input) |
Transmission output | Number of outputs: 2 4 mA to 20 mA DC/0 mA to 20 mA DC, input/output isolated type Maximum load resistance: 900 Ω Transmission output range: Freely selectable within the measurement range (Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.) |
Contact output | Number of outputs: 4 Alarm contact outputs (R1, R2, and R3) Contact type: relay contact, SPST (1a) Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis Selectable from the selected measurement, anomaly alarm, and maintenance. Alarm contact output (R4) Contact type: relay contact, SPDT (1c) Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis Selectable from the selected measurement, anomaly alarm, and maintenance. (However, R1 and R2, and R3 and R4 share the common contacts respectively.) |
Calibration function | Specific resistance: Based on the specified compensation coefficient for cell constant (parameter input) Temperature: Calibrated by comparing with the reference thermometer |
Communication output | RS-485 input/output |
Transmission output hold feature | - Previous value hold
- Optional value hold
Selectable from the above (However, only the previous value hold is available in the maintenance mode.) |
Self-diagnosis function | - Sensor diagnosis
Short-circuit and disconnection of the temperature sensor - Out of the measurement range
- Converter error
|
Temperature compensation | - Temperature compensation for extra-deionized water and impurities
Select the temperature characteristics of impurities - NaCl temperature characteristics - Arbitrary temperature coefficient entry (temperature coefficient: 5%/℃) Reference temperature: 5℃ to 95℃ - No temperature compensation is performed.
|
Temperaturecompensated range | 0℃ to 100℃ |
Extra deionized water specific resistance selection | Measurement unit | kΩ•m | 182.3 (standard), 181.8, 182.4 | Select from options shown on the left. |
MΩ•cm | 18.23 (standard), 18.18, 18.24 |
Clipping function | When the measured value is above the upper limit of the measurement range derived from the specified specific resistance, the specified resistance is used as the measured value. |
Ambient temperature | −5℃ to 45℃ |
Relative humidity | 20% to 85% (without dew condensation) |
Storage temperature | −25℃ to 65℃ |
Power supply | Rated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.) |
Structure | Indoor-use panel installation type Panel case: ABS, Terminal: PBT Panel: IP65 dust and water proof structure |
Protective structure | Panel: IP65 (IEC60529, JIS C0920) Rear case: IP20, Terminal:IP00 Class II device (IEC61010-1) Pollution level 2 (IEC61010-1) |
Conforming standards | CE Marking | EMC Directives: EN61326-2-3 Low Voltage Directive: EN61010-1 RoHS Directive: EN50581 |
FCC Rule | FCC Part15 |
External dimensions | 96 (W) mm × 96 (H) mm × 115 (D) mm Case depth: approx. 105 mm (when panel-mounted) |
Mass | Approx. 550 g |
Compatible sensors | ERD/ERF-series specific resistance sensor, cell constant 0.01/cm |